2 posts / 0 new
Last post
Pascal Laine
Sevcon fault

Hello there

When i change tuning, OVMS send me this message (then, tuning change and all works fine)

SEVCON Fault 0x4681 [Warning]: Unit in preoperational
Info: Controller is in pre-operational state
Action: If configured and ready for use; change state to operational.

Is it a problem ?

Cheers

Pascal

dexter
dexter's picture
Sevcon fault

That's normal. The tuning procedure switches back to operational mode when done.

Log in or register to post comments